Originally Posted by
Nigel Goodwin To calculate the resistance required is simple ohms law, assuming the meter is 1mA FSD, and you want to read 60KV FSD, simply divide the voltage by the current, so 60,000/.001 = 60,000,000 ohms. With a 100uA meter, it would (obviously) be 600,000,000 ohms. You should subtract the internal resistance of the meter from this value - but I think it's fairly obvious that a couple of 100 ohms from those values is a waste of time!.
You also need to be concerned with the voltage and wattage ratings, with a 1mA meter it will dissipate 60W, and with a 100uA meter it will dissipate 6W. Also resistors have voltage ratings, usually only a few hundred volts, so you need to use multiple resistors in series to withstand the voltages, or a smaller number of special high-voltage resistors in series. These special resistors are usually very high values as well, designed for this type of use.