    Latching relay vs. Solid state relay

    Hi all,

    I am doing a project where one of its functions is to switch off the water heater when a pre-set temperature is exceeded. One of the targets for this project is to keep it low in power consumption as possible.
    For this reason, i was considering using a latching relay so it wont be energized all the time, therefore consuming less power. Another option is to use a solid state relay (which as far as i know does not consume high power although it need continuous supply when contacts are closed).

    Which type of relay do you suggest? a latching relay or a solid state relay?

    Thanks in advance.

  2. #2
    Reloadron Reloadron is offline
    You do not mention the load current or voltage? However, using for example a SSR like this one the on current with 5 VDC applied for the On state the current draw is about 15 mA. Really depends on what is classified as a low on current? Then there is consideration for the other circuit components.

    Ron
    0
    Please do not PM me with forum related questions. Let's keep things in the open forum. Thank you.

  3. Thread Starter #3
    adrianvon adrianvon is offline
    Hi Ron,

    You do not mention the load current or voltage?
    The load voltage is 230VAC and the current is not known since it will be used on any water heater, but a 40A to 50A relay will be safe.

    The relay will be controlled from a PIC micro controller.

    Really depends on what is classified as a low on current?
    The less current consumed the better. What is the typical current consumption of a normal relay which can handle 230VAC 40-50A ? and will a lurching relay consume less then the SSR?

    Thanks.

    EDIT: will i need to use a heat sink if i used an SSR?
    0
    Last edited by adrianvon; 11th February 2012 at 11:19 AM.

  4. #4
    Boncuk Boncuk is offline
    Hi adrianvon,

    please let's be realistic.

    Water heaters are normally designed for 1KW, providing hot water for a single shower.

    There are 10KW water heaters on the market, but they are all three phase devices.

    So a 1KW heater would require ~4.5A at 230VAC.

    Solid state relays are designed for different AC voltages with and without zero crossing unit built in.

    Here is an SSR I suggest for your application: SHARP S202S02, rated 230V/8A with zero crossing unit.

    The LED forward voltage is 1.2V and the forward current is 8mA - no reason to use a mechanically latching relay since the heater will be switched on and off within short time intervals.

    Using an SSR it's advisable to use a 0.6W VDR across the AC terminals to avoid back firing into the built in triac.

    Have a look into the attached datasheet.

    For higher currents look into the second datasheet of Carlo Gavazzi SSRs. They should do for three phase high current heaters. Carlo Gavazzi SSRs are internally fitted with a snubber network.

    Boncuk
    Attached Files
    0
    Last edited by Boncuk; 11th February 2012 at 12:12 PM.

  5. Thread Starter #5
    adrianvon adrianvon is offline
    Hi,

    Thanks for your reply. Can you please explain to me what are 'zero crossing unit' and 'VDR ' ?

    I was considering the SSR in the link below. Is it good for my application?

    http://www.ebay.co.uk/itm/Single-Pha...item4843a6a3bb

    and will i need a heat sink for it ?

    Thanks.
    0

  6. #6
    Boncuk Boncuk is offline
    Quote Originally Posted by adrianvon View Post
    Hi,

    Thanks for your reply. Can you please explain to me what are 'zero crossing unit' and 'VDR ' ?
    A zero crossing unit fires the triac at zero AC voltage passing. A VDR is a "Voltage Dependent Resistor", taking care of eliminating sparks which "fly" between relay contacts when power is disengaged. There won't be sparks within a solid state relay, but using a properly rated VDR (e.g. 275V) it takes care of elimination of possible sparking.

    I was considering the SSR in the link below. Is it good for my application?
    Nobody knows the power rating of your heater yet!

    and will i need a heat sink for it ?
    That depends on the rated power of the heater and the SSR. The data sheet should have information about possible heatsinks for that.

    Thanks.
    0

  7. #7
    Boncuk Boncuk is offline
    Quote Originally Posted by adrianvon View Post
    Hi,

    Thanks for your reply. Can you please explain to me what are 'zero crossing unit' and 'VDR ' ?
    A zero crossing unit fires the triac at zero AC voltage passing. A VDR is a "Voltage Dependent Resistor", taking care of eliminating sparks which "fly" between relay contacts when power is disengaged. There won't be sparks within a solid state relay, but using a properly rated VDR (e.g. 275V) it takes care of elimination of possible sparking.

    I was considering the SSR in the link below. Is it good for my application?
    Nobody knows the power rating of your heater yet!

    and will i need a heat sink for it ?
    That depends on the rated power of the heater and the SSR. The data sheet should have information about possible heatsinks for that.

    Thanks.
    0

  8. Thread Starter #8
    adrianvon adrianvon is offline
    Hi,

    I was considering the SSR in the link below. Is it good for my application?
    Nobody knows the power rating of your heater yet!
    It is a 1500 Watt element water heater.
    0

  9. Thread Starter #9
    adrianvon adrianvon is offline
    Hi,

    I was considering the SSR in the link below. Is it good for my application?

    http://www.ebay.co.uk/itm/Single-Pha...item4843a6a3bb

    Nobody knows the power rating of your heater yet!
    It is a 1500 Watt element water heater.
    0
    Last edited by adrianvon; 11th February 2012 at 02:31 PM.

  10. #10
    Boncuk Boncuk is offline
    Sorry,

    the item has either been removed or is no longer available.

    I suggest to use the SHARP S202S02 SSR. It can switch up to 8A loads.

    At 6.525A (your heater) the power dissipation will be 8W. No info given about a heatsink in the datasheet. For safety reasons you might use a clip on heatsink.

    Boncuk
    0

12 Last »
Tags
Similar Threads
Thread Starter Forum Replies Last Post
Bidirectional solid state relay? Mosaic General Electronics Chat 6 8th February 2012, 05:25 AM
solid state relay mhtavallaie Electronic Projects Design/Ideas/Reviews 3 15th February 2005, 12:01 PM
Solid State alternative to relay, low latch V LiquidKernel General Electronics Chat 2 24th March 2004, 01:02 AM
Solid state relay questions PrL Electronic Projects Design/Ideas/Reviews 7 28th December 2003, 05:20 AM
Solid State Relay Help bryan Electronic Projects Design/Ideas/Reviews 2 25th June 2003, 08:17 AM
Electronic Circuits  |  Learning Electronics

Join our community with over 100,000 Members! It's free, easy and when you're logged in you have many more features! Click to register.
Page Time: 0.14005 seconds      Memory: 7,705 KB      Queries: 17      Templates: 0