| Electronic Projects Design/Ideas/Reviews Are you building an electronic project or want to? Maybe you need some assistance? Come and submit your electronic questions here and let our experienced members find a solution. |
| | LinkBack | Thread Tools | Display Modes |
| | (permalink) |
| Hi Guys... I am working with four 74190 counters in my projects each two of them form a counter one count up and the other count down.. The problem is that they start random.. How can i reset them to 99 or 00 at the beginning of the project... I NEED HELLP :shock: | |
| |
| | (permalink) |
| 74190 has an asynchronous Load and 4 data inputs. On the 2 up counters, set the data inputs to 0000. On the 2 down counters, set the data inputs to 1001 (9 decimal). To reset the counters, pulse the Load line low and back high. | |
| |
| | (permalink) |
| I will test it right now... (i tested it before) to let you know the project is a game that needs a countdown timer... So before pushing start the counter must be in the starting state i.e. 99 ... | |
| |
| | (permalink) |
| I made a small circuit connected to the start button.. Thanx man.. it's working 100% now.. | |
| |
| Bookmarks |
| Thread Tools | |
| Display Modes | |
| |