I have purchased a cheap secondhand transformer for an experiment that i hope i have chosen correctly?
If i am wrong please belt me across the ears at any stage!

I need to make sure i have the right thing not being sure about transformers & need some advice & also to make sure i have the wiring side of things correct before i go ahead.

I am hoping this is a Step-Down Transformer with the Output 12v AC 150amp as marked on it.

I have attached a couple of blury pictures of both sides of the transformer to show the connecting poles.

On one side --- Input side of the Transformer there are 5 poles marked:

( 0 100v 115v 220v 240v )

Our Mains power is 240v AC so, for the correct wiring as i see it, i connect:
The ACTIVE wire to the 240v pole,
The NEUTRAL wire to the 0 pole,
& the EARTH wire to the Chassis.

Is this correct?

I actually want to control this Transformer with a 240v AC 10amp VARIAC so i can vary the output.



On the other side --- output side of the Transformer there are two poles, for the ACTIVE & NEUTRAL wires. If this is correct doe's it make any difference what the ACTIVE or NEUTRAL poles are as they are not marked?

Thanks
Attached Images
File Type: jpg part 003.jpg (256.4 KB, 28 views)
File Type: jpg part 005.jpg (247.6 KB, 25 views)
codan is offline  
Old 15th April 2008, 07:48 AM   (permalink)
Default

Quote:
Our Mains power is 240v AC so, for the correct wiring as i see it, i connect:
The ACTIVE wire to the 240v pole,
The NEUTRAL wire to the 0 pole,
& the EARTH wire to the Chassis.
That is correct.

The output 12 volts at 150 Ampères equals to 1800 VA or Watts
Your primary current will be 7.5 Amps at 240 Volts.

A 10 Amp variac should be fine.

We call the (poles) Taps in the trade

Regards, Raymond
__________________
There are more ways to get to Rome.

Electricity, Electric clocks, Meters and Trains are great.
RODALCO is offline  
Old 15th April 2008, 07:55 AM   (permalink)
Default

To check the secondary voltage, use a voltmeter.
It may be a little higher than 12 volts with no load connected to the TX.

The polarity doesn't matter here.

It pays also to check that the primary and secondary coils are insulated properly from each other. It looks as a TX with 2 separate windings from your photo.
And it is a step down TX according to the data from the photo.

What are you planning to drive with it !!
__________________
There are more ways to get to Rome.

Electricity, Electric clocks, Meters and Trains are great.
RODALCO is offline  
Old 15th April 2008, 08:37 AM   (permalink)
Default

Looks good codan!
Though I would test the used tranformer first -to assure it is working properly. An ohm-meter will let you know if there are any short circuits between any winding and the transformer core. Though testing for any possible short circuits between wire windings will have to be done by monitoring the power in/out-which is approximately equal (assumming high 90`s efficeincy). Using your variac set low (slowly stepping up), with no load attached measure the output voltage. If all is good, attach a load and test again. Also, the output is isolated from the hot and neutral-therefore they are electrically the same.

Last edited by second286; 19th April 2008 at 02:16 PM.
second286 is offline  
Old 15th April 2008, 08:51 AM   (permalink)
Default

Thanks Raymond,

I have checked the Primary & Secondary windings to make sure there isolated from each other, i only used a multimeter continuity test though.
According to that the insulation is ok.

TX ? What does this mean, Coils? I thought it meant Transmit coil or is it one & the same?
Like RX is Reciever Coil is it not?

" What are you planning to drive with it !! "

I have designed & built a small eddy current retarder -- electromagnetic brake for a small dyno which will require around 12vDC & 100amps or better for full load.
I need to rectify the AC from the Transformer via an AC/DC convertor. This will get me testing some things, the Variac will manually vary the output for the load.

Once i can test some things i will then try to control it with electronics & then onto computer. This is a long way off though as i am still fumbling around like a real novice with learning the electronics side of things.

Only one way to learn though!
codan is offline  
Old 15th April 2008, 08:57 AM   (permalink)
Default

Quote:
Originally Posted by second286
Looks good godan!
Though I would test the used tranformer first -to assure it is working properly. An ohm-meter will let you know if there are any short circuits between any winding and the transformer core. Though testing for any possible short circuits between wire windings will have to be done by monitoring the power in/out-which is approximately equal (assumming high 90`s efficeincy). Using your variac set low (slowly stepping up), with no load attached measure the output voltage. If all is good, attach a load and test again. Also, the output is isolated from the hot and neutral-therefore they are electrically the same.
Thanks second286,

I will certainly take your advice on checking things out properly, like mentioed i have only done a continuity test with a multimeter. I will check things out properly now though.
codan is offline  
Old 15th April 2008, 09:44 AM   (permalink)
Default

TX is just short for transformer.

Cheers, Raymond
__________________
There are more ways to get to Rome.

Electricity, Electric clocks, Meters and Trains are great.
RODALCO is offline  
Old 21st April 2008, 04:33 PM   (permalink)
Default

on the secondary side, it says 150A INT, so it is not continuously rated. It may well give 100A continuous though. It really depends how intermittent the 150A loading was intended to be. Ideally you need to know the duty cycle and time frame.

it's a big beastie though, so will warm up slowly. just keep an eye on how warm it gets. if you can't keep your hand on it, then kee both eyes on it
__________________
Transformers are work
Electronics is a hobby
grim is offline  
Reply

Bookmarks

Thread Tools
Display Modes



Similar Threads
Title Starter Forum Replies Latest
Transformer Question firealarmfreak Electronic Projects Design/Ideas/Reviews 5 3rd March 2008 02:40 PM
Problems selecting a PCB Transformer NewcastleSAR Datasheet/Parts Requests 31 4th January 2007 08:16 PM
[i]TDA3566[/i] ADVICE REQUIRED olly_k Datasheet/Parts Requests 7 9th June 2004 02:50 AM
wounding a transformer farnoosh General Electronics Chat 0 6th June 2004 07:48 AM
A little transformer advice wanted ... john1 Electronic Projects Design/Ideas/Reviews 8 13th October 2003 10:17 PM



All times are GMT. The time now is 12:49 AM.


Electronic Circuits  |  Learning Electronics
Powered by vBulletin® Version 3.7.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.

eXTReMe Tracker